Self-priming centrifugal pumps E

Self-priming centrifugal pumps E

E Series, self-priming, centrifugal pumps are used for dirty water applications. These pumps use re-circulation of liquid in the pump casing to remove air from the suction line, enabling the pump to draw liquid through the suction line. These pumps are also available with a petrol or diesel engine.
 
APPLICATIONS
  • Industry
  • Farming
  • Agricultural / Farming
  • Waste treatment
  • Naval duty
  • Civil engineering
 
FEATURES
  • Robust construction
  • Quick self-priming
  • Easy maintenance
  • Solids handling
  • Reliable, wear resistant
  • Various material to suit application
  • 17mm free passage
  • 1.1 kW
  • 50mm outlet
Self-priming centrifugal pumps J

Self-priming centrifugal pumps J

INDUSTRY
• Transfer: clean, dirty, containing sand in suspension, muddy, neutral, alkaline, acidic liquids; low viscous petroleum products, solvents even if dirty; milk of lime, caustic soda; washing, cooling, recirculation, smoke scrubbing 
• Treatment: pumping polluted, hot or corrosive waste water containing sand, mud or solids in suspension; dosing neutralising liquids; pumping out settled sludge
• Naval: loading and unloading; bilge pumping; washing, fire-fighting, stripping, sanitary duty and circulation
• Agriculture: surface irrigation; liquid manure oxygenation; transfer and spraying liquid manure or fertilisers; distribution of liquid animal feed; transfer of must; washing. 
CONSTRUCTIONS
• Drainage of excavations, canals or ponds
• Ground water dewatering with drains
• Water supply from wells or canals
• Washing concrete castings and aggregate
• Recirculation of bentonite and drilling mud.
SAFETY
• Drainage after flooding or terrential rains
• Emergency duty: temporary sewage pumping; fire fighting; recovery of dangerous liquids. 
Self-priming centrifugal pumps J TRM

Self-priming centrifugal pumps J TRM

Operating principle: drive
Founded on the natural repulsion of magnets, the magnetic drive is a power transmission without any physical contact between the engine and operating unit. The magnetic cores are keyed on to the drive shaft and impeller shaft respectively. A containment element is placed between the two cores, sealing the mechanical pumping unit. This means there is no way the liquid can escape. The system is a synchronous one, i.e. both the driving and driven shaft have exactly the same rotation speed.
 
Operating principle: J-TRM pumps
Air (yellow arrows) is drawn into the pump by the vacuum produced as the impeller rotates and is emulsioned with the liquid (blue arrows) contained in the pump casing. The air/liquid mixture is driven into the priming chamber where the air, which is less dense, separates out and vents through the delivery line while the liquid, due to the higher density, falls back and is recirculated. When all the air has been evacuated from the suction line, the pump primes and operates like a normal centrifugal pump. It can also handle a mixture of air and liquid. The check valve mounted in the pump suction port serves two purposes: it prevents the liquid from draining out of the suction line when the pump is not in operation, and if the suction line is drained by accident, enough liquid is retained in the pump casing for the pump to reprime. The delivery line must allow the air drawn from the suction line to vent to atmosphere.
Self-priming trash pumps ST

Self-priming trash pumps ST

Varisco ST-R series pumps are recirculating self-priming pumps suitable for handling liquids with large solids in suspension. They are mounted above and out of the liquid to be pumped, enabling inspection and maintenance of the pump, drive and motor  with greatly reducing health and safety hazards for maintenance personnel. The special design of the volute enables the pumps to prime and reprime automatically even without check valves. If the impeller should be clogged by rags or stringy materials, the large front cover can easily be removed to provide full access for inspection and maintenance. The entire rotating assembly can be removed from the pump casing without dismantling the pipes. Varisco ST-R self-priming trash pumps are your best choice for difficult pumping applications: solid construction, easy installation and maintenance, replaceable wear parts. They feature both front and rear wear plates, protecting both the impeller and the seal housing from wear and reducing overall maintenance costs.
 
• Sewage lift stations
• Sewage treatment
• Industrial wastewater treatment
• Pumping liquids with high concentrations of solids in suspension
• Sewer by-pass
Rapid self-priming without foot valve. Once filled with water, the pump is
automatically primed to a height of 7,5 m.
• Two vane, semi-open impeller handling solids up to 3” (75 mm) in diameter.
• Front and rear wear plates with oil resistant rubber facing (except ST-R8) to protect the faces of the impeller vanes from wear due to small abrasive particles. This feature ensures as new performance and priming capabilities well into the service life of the wear parts. 
• The front wear plate can easily be adjusted from the outside to compensate for wear, if necessary.
• Self-aligning oil lubricated mechanical seal with tungsten carbide faces and Viton® elastomers.
• Full access to the impeller and mechanical seal for inspection and maintenance without removing the pipework or the rotating assembly.
• Removable rotating assembly. The entire assembly slides out of the back of the pump without dismantling the casing and pipework.
 • Pump casing can easily be flushed with water before opening through the top cover and drain.
• Dual protection of bearings through double oil bath, with intermediate discharge to atmosphere, to isolate the oil in the bearing housing from the oil in the mechanical seal. Leakages can be monitored through the intermediate chamber.
• Check valve can easily be replaced through the impeller inspection cover without dismounting the pipework.

 

Self-priming centrifugal pumps MA

Self-priming centrifugal pumps MA